Kód: | SW-DRV-MARPOSS |
Driver pro načítání dat ze software Merlin přes rozhraní RS232.
Nastavení v software Merlin:
RS232
Baudrate: | 9600 |
Bit: | 8 |
Parity: | None |
StopBit: | 1 |
Výstupní protokol
Standard protocol N°3 (DOP-STD03)
START
Name |
Characters |
Meaning |
Start |
1 |
Start message character: <STX> |
GLOBAL DATA
Name |
Characters |
Meaning |
Date |
8 |
Date test was performed in "DD/MM/YY" format |
Hour |
8 |
Time test was performed in "HH:MM:SS" format |
Program |
20 |
Name of part program used |
Serial number |
20 |
Serial number or progressive number of piece within the active batch |
Piece result |
2 |
Code that indicates the result of the measurement performed on the piece: G (good), T (trend), R(reject), NV(not valid) |
Number of characteristics |
2 |
Number of characteristics sent (only non auxiliary characters are sent) |
|
2 |
<CR><LF> |
CHARACTERISTIC DATA
The following information is sent for each characteristic
Name |
Characters |
Meaning |
Name |
3 |
Name of the characteristics. |
Index |
2 |
Characteristic exportation index (number between 01 and 16) that determines the order in which it is exported. This value is setup by the administrator level user in the characteristic programming window. |
Value |
12 |
Absolute or relative measurement value, as displayed. The value is formatted according to the precision setup for the characteristic. The decimal separator is always represented by a point. The sign is always indicated. |
Measurement unit |
4 |
Measurement unit symbol, as displayed µm, mm, °C...) |
Result |
3 |
Code that indicates the result of the measurement performed on the single characteristic: G,T+,T-,R+,R-,NV+,NV- |
Class |
5 |
Characteristic classification code, calculated on the basis of the measurement value, in accordance with the table selected during the programming phase. If the classification code is not required for the characteristic a series of space characters is sent instead. |
|
2 |
<CR><LF> |
EXAMPLE OF DATA OUTPUT
In the following example, the values of two measurements (OG1 with exportation index 01 and OP1 with exportation index 02) performed on good piece number 11 using the Biella program are transferred. The classification for the first measurement value is 02 for the second it is 05:
<STX>
10/01/0815:10:01Biella______________11__________________G_2_<CR>< LF> OG101+24.1234____μm__G__02___<CR><LF>
OP102-12.123_____μm__G__05___<CR><LF>
<ETX>
Legend
<STX> character ASCII 2
<ETX> character ASCII 3
<LF> character ASCII 10
<CR> character ASCII 13
_ ASCII space character 32
© Copyright 1992 - 2024 PALSTAT s.r.o. |
PALSTAT s.r.o. Bucharova 230 543 02 Vrchlabí CZECH REPUBLIC |