DRIVER MARPOSS MERLIN

Kvalita » Propojení » Drivery »

Driver Marposs Merlin
Driver Marposs Merlin
Print
Kód: SW-DRV-MARPOSS

Základní informace

Driver pro načítání dat ze software Merlin přes rozhraní RS232.

 

Nastavení

Nastavení v software Merlin:

RS232

Baudrate: 9600
Bit:   8
Parity:   None
StopBit: 1


Výstupní protokol
Standard protocol N°3 (DOP-STD03)

 

Výstup dat

START

Name

Characters

Meaning

Start

1

Start message character: <STX>

 

GLOBAL DATA

Name

Characters

Meaning

Date

8

Date test was performed in "DD/MM/YY" format

Hour

8

Time test was performed in "HH:MM:SS" format

Program

20

Name of part program used

Serial number

20

Serial number or progressive number of piece within the active batch

Piece result

2

Code that indicates the result of the measurement performed on the piece: G (good), T (trend), R(reject), NV(not valid)

Number of characteristics

2

Number of characteristics sent (only non auxiliary characters are sent)

 

2

<CR><LF>

 

CHARACTERISTIC DATA

The following information is sent for each characteristic

Name

Characters

Meaning

Name

3

Name of the characteristics.

Index

2

Characteristic exportation index (number between 01 and 16) that determines the order in which it is exported. This value is setup by the administrator level user in the characteristic programming window.

Value

12

Absolute or relative measurement value, as displayed. The value is formatted according to the precision setup for the characteristic. The decimal separator is always represented by a point. The sign is always indicated.

Measurement unit

4

Measurement unit symbol, as displayed µm, mm, °C...)

Result

3

Code that indicates the result of the measurement performed on the single characteristic:

G,T+,T-,R+,R-,NV+,NV-

Class

5

Characteristic classification code, calculated on the basis of the measurement value, in accordance with the table selected during the programming phase. If the classification code is not required for the characteristic a series of space characters is sent instead.

 

2

<CR><LF>

 

EXAMPLE OF DATA OUTPUT

In the following example, the values of two measurements (OG1 with exportation index 01 and OP1 with exportation index 02) performed on good piece number 11 using the Biella program are transferred. The classification for the first measurement value is 02 for the second it is 05:

 

<STX>

10/01/0815:10:01Biella______________11__________________G_2_<CR>< LF> OG101+24.1234____μm__G__02___<CR><LF>

OP102-12.123_____μm__G__05___<CR><LF>

<ETX>

 

Legend
<STX>   character ASCII 2
<ETX>   character ASCII 3
<LF>      character ASCII 10
<CR>     character ASCII 13
_             ASCII space character 32

 


https://www.palstat.cz/ - Systém řízení kvality Ubytování ve Vrchlabí